Commercial Fire Rated Roller Shutters

Staffordshire Doors Fire Rated Commercial Roller Shutters

Commercial Fire Rated Roller Shutters

Fire protection is fast becoming a major consideration for many new build and refurbishment projects, particularly in the locality of kitchen and cooking areas / serveries where potential fire hazards are a real risk.  And we’re also aware that, especially in areas like receptions and serveries, you want it to look good, too.

Our innovative, bespoke range of stylish and effective Flameshield Shutters gives you the fire-safety protection you need, with clean lines and discreet internal motors also enhancing the aesthetics of your secured premises. Both the Flameshield 120 Commercial Shutter and the heavy-duty 240 Industrial version are fully compliance-tested, suitable for a wide range of locations and applications and can be powder-coated in a colour of your choice.

Fire Rated Roller Shutter Features

  • Internal tubular motor
  • Stylish design to assist building aesthetics
  • Battery back up for power failure
  • Low voltage switching
  • Fire signal relay release
  • Fully controlled descent
  • Audiovisual option to warn of fire shutter in operation with voice record
  • 50 mm flat lath option
  • Powder coating option to compliment building fabric
  • Assessments for widths up to 10m wide

Flameshield 120 Commercial Shutter

Staffs Industrial Doors Ltd Commercial Fire Rated Shutters
Staffs Industrial Doors Ltd Commercial Fire Rated Shutters

In the past, choosing a fire shutter has been about selecting the right one for job – but now A1S has developed the Flameshield 120 commercial fire shutter to enable the aesthetics of the application to be taken into consideration.

For commercial applications, like receptions and serveries, for example, the clean lines and internal motor of the Flameshield 120 commercial fire shutter provide a stylish solution to fire safety demands.

Release Mechanisms

Fire relay and key switch (requires maintained supply, battery back up needed if no maintained supply). Fire relay, key switch and fusible link if no fire alarm.

Fire Relay

Principally the commonly used means of release, the characteristics mimic the use of the solenoid on the conventional fire shutter, again linked to the fire alarm, the shutter rather than closing manually through the gearbox will of course be powered down. A volt free signal is required from the fire alarm.

Fusible Link Release

On activation, the link which is a soldered link, separates and releases at 64 degrees centigrade, in effect the temperature release of the link creates a signal to the relay which in turn powers the door down.

Audio Visual Warning (FDI)

Principally this unit is designed to delay the closing of the fire shutter: generally the fire alarm is linked to the audio visual unit and from the audio visual unit straight into the key switch. There is no need for a separate relay: there is already a relay in the FDI. On activation from the fire alarm the unit starts to “flash & sound”, this unit contains a programmable timer which effectively delays the signal to the relay in the panel to close the door. 230mm wide x 240mm long x 120mm deep.

Size Parameters

The shutter test relates to the 1HR/2HR fire resistance. The shutters are generally intended for protection of a range of openings in masonry / concrete, steel, steel stud or timber partitions. The maximum clear openings are for 4000mm wide x 2500mm high, or in a partition system for 1 hour up to an area of 10sq mtrs, principally this incorporates the BRE test FG 7941N which relates to a tested fire shutter in a stud partition, the opening must be fire rated to suit and be capable of carrying the weight of the shutter. Where the shutters are used to protect serveries it is assumed that the counter is composed of non-combustible material and the counter is of sufficient width to ensure that the bottom rail movement under heating cannot result in the rail overhanging the counter. Shutters over 3500mm up to 4800mm will be traditional curved 75mm lath construction, based on a maximum area of 10sq mtrs. Shutters under 4000mm clear width will have 50mm guides and shutters over this width will have the traditional 65mm guides.

Battery Back Up Unit

Principally the tube motor fire shutter requires a maintained supply. If this cannot be achieved then effectively the shutter will require a battery back up unit. If under fire conditions there is a power failure, the shutter must have a means of ensuring closure, the unit provided will give the facility for at least one operation under fire conditions. The dimensions of the battery backup are 200mm (wide) x 130mm (long) x 70mm (deep)

Paint Finish Option

To compliment the aesthetics of your application, this product can be power coated to any BS or RAL colour (subject to availability)


Roller Shutter Fire Rating Test Results

Fire rates roller shutter doors have to pass a rigorous safety test to ensure they are fully compliance-tested.  Certified to 1hr, 2hr and 4hr, Staffs Industrial Doors Ltd’s fire rated roller shutter doors provide resistance to both intruders and the damaging and potentially devastating effects of fire.

The Flameshield 120 commercial fire shutter was successfully tested at the Warrington Fire Research Establishment and is constructed to WARRES No.145904 – the test is in accordance with clause 8 of BS476 part 22: 1987

Staffordshire Industrial Doors Fire Rated Shutters

Commercial Fire Rated Roller Shutters

Staffs Industrial Doors Ltd Commercial Fire Rated Shutters
Staffordshire Industrial Doors Commercial Fire Rated Shutters
Staffordshire Industrial Doors Commercial Fire Rated Shutters
Staffs Industrial Doors Ltd Commercial Fire Rated Shutters

Call our sales team on 01782 566810 to discuss how we can help secure your property